Account shall be taken of the load effects of potentially excessive snow accumulation in pockets or wells of roofs or decks.
Roof snow load zones for ny.
However for roofs having a non slippery.
In areas of the state outside of certified local government jurisdictions the design snow load shall be based on the ground snow loads developed in snow loads for structural design in montana authored by f f.
You can click on the map below to find the design ground snow load for that location.
On the low roof if proper snow guards are provided on the high roof.
The north zone design live load equates to 40 pounds per square foot the middle zone equates to 30 pounds per square foot and the south zone equates to 20 pounds per square foot.
The minimum design roof snow load.
As an example the flat roof snow load for a roof located in a 55 psf snow z one is typically 70 of 55 or 38 5 psf.
By multiplying the gsl by 0 7 or 70 of the ground snow load.
This downward imposed load on the home is also known as the snow load.
The north zone middle zone and the south zone are identified on the roof load zone map above.
The total roof snow load including additional loading effects due to drifting snow sliding snow unbalanced loading conditions and partial loading conditions shall not be less than 40 psf for roofs with a slope less than or equal to 5 degrees and shall not be less than the slope factor c s times 40 psf for roofs with a slope greater than 5 degrees.
The ground snow loads to be used in determining the design snow loads for roofs shall be determined in accordance with asce.
Where flat roof snow loads exceed 30 psf 1 44 kn m 2 20 percent shall be combined with seismic loads.
Schilke civil agricultural engineering montana state university august 1989.
A great deal of confusion currently exists among engineers architects recreation specialists and maintenance personnel concerning the proper snow loading to use for the design and maintenance of trail bridges building roofs and other structures in mountainous high snow load areas.
Edition of the residential code of new york state.
1610 8 snow pockets or wells.
Apa e30 01 american plywood association engineered wood construction guide e 30 indicates that 7 16 osb for roof sheathing with supports 24 o c.
Crane hook loads need not be combined with roof live load or with more than three fourths of the snow load or one half of the wind load.
Until that time reference standard e 30 is to be utilized for selection of roof and floor plywood sheathing.
Why snow load information.
Flat roof snow loads of 30 psf 1 44 kn m 2 or less need not be combined with seismic loads.
Use our new york ground snow loads map to easily determine the ground snow load 2010 building code of new york state.
In this case the sloping roof with snow guards shall be designed for the unit snow loads required for a flat roof.
If you live in the us our snow load calculator compares the total weight on your roof with the permissible load calculated according to the standards issued by the american society of civil engineers regarding the minimum design loads for buildings and other structures asce7 16.